Testing Machine and Electronic Control Functions
53
F8237701
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Table 16 (continued)
Production Test Cycle Quick Reference Chart
Display Test Mode Comments
“S2” for supply or
“C2Ho” for
compartment
Supply #2 or Compartment
#2 Hot Fill
“S3” for supply or
“C3Co” for
compartment
Supply #3 or Compartment
#3 Cold Fill
“S4” for supply or
“C4Ho” for
compartment
Supply #4 or Compartment
#4 Hot Fill
“xxxF” degrees F or
“xxxC” degrees C
depending on the
Fahrenheit/Celsius
programming parameter
Heat water to 110°F or
display temperature
xxx is degree temperature. This step skipped if not model with
heat. Heater turned off when temperature reached.
“LoAg” Reduced Wash Speed
Forward with no agitation
action
This step skipped on 2 Speed Models.
“Ag” Wash Speed Forward with no
agitation action
“rAg” Wash Speed Reverse with no
agitation action
“drAI” Drain Distribution Speed
“PUrg” Factory Valve Purge
“SP 1” Extract Speed #1 “very low” This step skipped on 2 Speed Models.
“SP 2” Extract Speed #2 “low” This step skipped on 2 Speed Models.
“SP 3” Extract Speed #3 “medium” This step skipped on 2 Speed Models.
“SP 4” (VFD Models)
or
“SPIn” (2 Speed
Models)
Extract Speed #4 “high” Design 2 models only. This step skipped on Design 2 F-Speed
Models.
“SP 5” Extract Speed #5 “very high” Design 2 models only. This step skipped on Design 2 2 Speed and
F-Speed Models.
“SP 6” Extract Speed #6 “ultra high” Design 2 models only.
“Prdn” End of test Turn Power off