Programming Control
F8237701
18
Figure 5
CHM1391R
CHM1391R
(continued)
(continued) (continued)
“SUPL” - Program supply step options
“dISP” Dispenser Options:
Press START (enter) to access options
“SdUr” Supply Duration:
Press START (enter) to access options
“AdUr” - Agitate Duration (min):
“1” - “30”
“AgSt” - Program agitate step options
“drAn” - Enable/disable drain step
“SPIn” - Program extract step options
“SUEn” - Supply Step Enable/Disable:
“on” = Enabled
“oFF”” = Disabled
“AgEn” - Agitate Step
Enabled/Disabled:
“on” = Enabled
“oFF” = Disabled
“SSEC” - Extract Seconds:
“0” - “59”
“SPEn” - Extract Step
Enabled/Disabled:
“on” = Enabled
“oFF” = Disabled
“SSPd” - Extract Speed
Design 1 - (VFD only):
F-speed models use speeds 1-3,
1 = Very Low Speed (80)
2 = Low Speed (80)
3 = Medium Speed (100)
“HEAt” - Heat in Agitate
(heat present only):
“oFF” = Disabled
“1” = To Target
“2” = Maintain
Drain Step:
“on” = Enabled
“oFF” = Disabled
“SEC” - Seconds:
“0” - “59”
“Cnin” - Cycle Time
“0” - “255”
“nIn” - Minutes:
“0” - “9”
“SnIn” - Extract Minutes:
“1” - “3” (Intermediate Step)
“1” - “9” (Final Step)
“SSPd” - Extract Speed
Design 2 - (VFD only):
F-speed models use speeds 1-3,
1 =Very Low Speed (27)
2 = Low Speed (80)
3 = Medium Speed (100)
4 = High Speed (125)
5 =Very High Speed (150)
6 = Ultra High Speed (200)
“S4” - Supply #4:
“on” = Enabled
“oFF” = Disabled
“C2” or “S1” -
Compartment #2/
Supply #1:
“on” = Enabled
“oFF” = Disabled
(Design 1 Models)
“C3” or “S2” -
Compartment #3/
Supply #1:
“on” = Enabled
“oFF” = Disabled
(Design 1 Models)
“C4” or “S3” -
Compartment #4/
Supply #3:
“on” = Enabled
“oFF” = Disabled
(Design 1 Models)
“C2” - Compartment #2
“on” = Enabled
“oFF” = Disabled
(Design 2 Models)
“C3” - Compartment #3
“on” = Enabled
“oFF” = Disabled
(Design 2 Models)
“C4” - Compartment #4
“on” = Enabled
“oFF” = Disabled
(Design 2 Models)
“S1” - Supply #1
“on” = Enabled
“oFF” = Disabled
(Design 2 Models)
“S2” - Supply #2
“on” = Enabled
“oFF” = Disabled
(Design 2 Models)
“S3” - Supply #3
“on” = Enabled
“oFF” = Disabled
(Design 2 Models)