Alliance Laundry Systems HCN020HCF Instruction Manual Page 53

  • Download
  • Add to my manuals
  • Print
  • Page
    / 70
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 52
Testing Machine and Electronic Control Functions
51
F8237701
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Drive Software Version Number Test
(Design 2 models only)
This option displays the custom drive software version
number. To start test, control must be in the Diagnostic
Testing Mode. Refer to How to Enter Diagnostic
Testing Feature at the beginning of this section.
To enter, press the START (enter) keypad. The display
will show “drxx” where “xx” is the custom drive
software version number.
To exit the Custom Drive Software Version Number
Test, press the DELICATE WARM (<) keypad. The
control will return to the Diagnostic Testing Mode.
Drive Parameter Table Version Number
(Design 2 models only)
This option displays the custom drive parameter table
version number. To start test, control must be in the
Diagnostic Testing Mode. Refer to How to Enter
Diagnostic Testing Feature at the beginning of this
section.
To enter, press the START (enter) keypad. The display
will show “dPxx” where “xx” is the custom drive
parameter table version number.
To exit the Custom Drive Parameter Table Version
Number Test, press the DELICATE WARM (<)
keypad. The control will return to the Diagnostic
Testing Mode.
Drive Type Value (Design 2 models only)
This option displays the custom drive type value. To
start test, control must be in the Diagnostic Testing
Mode. Refer to How to Enter Diagnostic Testing
Feature at the beginning of this section.
To enter, press the START (enter) keypad. The display
will show “dt x” where “x” is the custom drive type
value. Refer to Table 15.
To exit the Custom Drive Type Value, press the
DELICATE WARM (<) keypad. The control will
return to the Diagnostic Testing Mode.
Production Test Cycle
To Enter Production Test Cycle
1. Be certain control is in Ready Mode and top
cover or coin vault is open.
2. While pressing and holding the Cold keypad with
one hand, press the Quick Hot keypad with the
other hand.
3. When the control enters the Production Test
Cycle, it will first display “S xx” with the “xx
showing the software version of the front end
control.
4. The control will advance through the sequence of
test steps whenever any key is pressed. Refer to
Table 16 for all tests in the Production Test
Cycle.
Display Drive Type
dt 1 2 HP drive
dt 2 3 HP drive
dt 3 5 HP 280V drive
dt 4 5 HP 480V drive
Table 15
Page view 52