Error Codes
F8237701
56
Table 17 (continued)
Display Description
Cause/
Corrective Action
E LF**
Water Leak Detection Error Control senses an increase in water level during
diagnostic testing. Power down machine to clear.
Control shows error after door is open (when cycle is
completed) for one minute or after test has been
completed, the right-most decimal point on display
lights* and the error information will be logged in audit
data.
Ed01**
SPI Communication Error Front End control cannot communicate with motor
drive. Power down, verify input power and 6-pin
communication connection on drive and Front End
control, power up and try again.
Ed02**
DC Bus Error The control detects the DC bus is too high. Power down,
verify line voltage is within specification, power up and
try again.
Ed03**
Tachometer Error The drive detects the tachometer input is damaged
during power up or no tachometer signal is detected
after initiating motor output. Power down, verify H3 on
drive and tachometer connections on motor, power up
and try again.
Ed04**
Locked Rotor Error Motor does not reach speed at startup. Power down,
verify motor mounting and look for obstructions, power
up and try again.
Ed05**
IGBT Overcurrent Error The drive detects an overcurrent shunt condition. Power
down machine for a minimum of two minutes, verify the
motor is not shorted phase to phase or phase to ground.
Power up and try again. If problem persists, replace
drive.
Ed06**
Thermal Error The control detects a high IPM temperature. Power
down, verify convection around drive heat sink, power
up and try again.
Ed07**
No Setup Error The drive receives movement commands without
receiving a setup packet. Power down, power up and try
again.
Ed08**
Max Over Current Error The drive detects motor output overcurrent condition.
Power down, power up and try again.
Ed09**
Current Sensor Error The drive detects a current sensor is not operating
properly at startup. Power down, power up and try again.
If problem persists, replace drive.