Page view 56
Error Codes
55
F8237701
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Table 17 (continued)
Display Description
Cause/
Corrective Action
E do
Door Open Error Control detects door open. Caused by pulling on door
while locked or about to lock. Correct inoperative door
locking system. End cycle. Power down machine to
clear.
E Ub
Unbalance Error Unable to balance load. Redistribute load and run cycle.
door
Door Open Indicator Door is not closed in Start Mode. If door is closed, check
for improper wiring or faulty door switch.
Err
Coin Error Invalid coin pulse or inoperative coin sensor. Check coin
drop area and remove obstructions. If error persists,
tampering may have occured. Evaluate security
procedures.
E dr
Drain Alarm Error Machine not drained within 15 minutes (or other
programmed length of time) in any drain step. End
cycle. Power down machine to clear.
E Ht
Heat Alarm Error Programmed heat alarm time of 120 minutes or other
programmed length of time is exceeded. Turn off heater
output for remainder of cycle.
E oP
Open Temperature Sensor Error Control senses temperature less than 0°F (-18°C) in
machine equipped with temperature sensor. Heater and
thermistor related operations are disabled.
E SH
Shorted Temperature Sensor Error Control senses temperature greater than 220°F (104°C)
in machine equipped with temperature sensor. Heater
and thermistor related operations are disabled for
remainder of cycle.
E ro
Rotation Sensor Error Invalid signal received from Rotation Sensor. Control
will activate coast times to complete cycle.
E FS
Frame Balance Switch Error Control detects Frame Balance Switch open. End cycle.
E db
Drive Balance Switch Error Control detects VFD Balance Switch input closed at
start of drain step. End cycle. Power down machine to
clear.
E Ld
Water Leak Detection Error If control senses a drop in water level during diagnostic
testing. Power down machine to clear. Control shows
error after door is open (when cycle is completed) for
one minute, lights the right-most decimal point* on
display and the error information will be logged in audit
data.
E Sd
Slow Drain Error Control shows error after door is open (when cycle is
completed) for one minute, lights the right-most decimal
point* on display and the error information will be
logged in audit data.
*To clear the decimal point on display, press the START (enter) button 3 times in succession (within 5 seconds).
**Design 2 models only.
Table 17 (continued)