Programming Control
39
F8237701
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
12. Supply/Compartment Dispenser
Programming “SUPC” (Design
1 Models Only)
This option allows the owner to choose between the
supply dispenser or compartment dispenser.
NOTE: Supply Dispenser must only be selected if
machine is connected to an external chemical
supply system.
How to Program Supply/Compartment
Dispenser Programming
1. Control must be in Manual Mode. Refer to
Entering the Manual Mode.
2. Press the Cold ( ) or the Delicate Cold ( )
keypad until “Prog” appears in the display. Press
the START (enter) keypad, and “AtS” will
appear in the display.
3. Press the Cold ( ) or the Delicate Cold ( )
keypad to scroll through the programmable
options until “SUPC” appears in the display.
4. When “SUPC” appears in the display, press the
START (enter) keypad. The current dispenser
option will appear in the display.
S” = Supply Dispenser
C” = Compartment Dispenser (Default setting)
5. Press the Cold ( ) or the Delicate Cold ( )
keypad to change the dispenser type.
6. Press the START (enter) keypad when the
desired dispenser type appears in the display. The
next option, “bALr” (VFD models) or “IrA”
(2 speed models), will appear in the display.
NOTE: For VFD models: To program “bALr”
(Number of Balance Retries), refer to option 13.
For 2 speed models: To program “IrA” (IR Access
[on/off]), refer to option 14. To program other
options, refer to the appropriate section.
How to Exit Programming Feature
Press the Delicate Warm (<) keypad until the control
returns to Ready Mode.
13. Number of Balance Retries
“bALr” (Variable Frequency
Drives Only)
This option allows the owner to program how many
times the control will retry balancing the load before
moving into Extract step.
How to Program Number of Balance
Retries
1. Control must be in Manual Mode. Refer to
Entering the Manual Mode.
2. Press the Cold ( ) or the Delicate Cold ( )
keypad until “Prog” appears in the display. Press
the START (enter) keypad, and “AtS” will
appear in the display.
3. Press the Cold ( ) or the Delicate Cold ( )
keypad to scroll through the programmable
options until “bALr” appears in the display.
4. When “bALr” appears in the display, press the
START (enter) keypad. The current value will
appear in the display.
5. Press the Cold ( ) or the Delicate Cold ( )
keypad to increase or decrease the current value.
NOTE: The number of balance retries can be set
from 1-7. Default balance retries is 3 for Design 1
models and 1 for Design 2 models.
6. Press the START (enter) keypad when the
desired value appears in the display. The next
option, “IrA”, will appear in the display.
NOTE: To program “IrA” (IR Access [on/off]),
refer to option 14. To program other options, refer
to the appropriate section.
How to Exit Programming Feature
Press the Delicate Warm (<) keypad until the control
returns to Ready Mode.
>
>
>