Alliance Laundry Systems HCN020HCF Instruction Manual Page 19

  • Download
  • Add to my manuals
  • Print
  • Page
    / 70
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 18
Programming Control
17
F8237701
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Manual Programming
Figure 4
CHM1319R
“Prog” Enter Program Mode
“AtS” - Set vend price for all cycles.
“dEn1” - Set value for the #1 coin entered.
“dEn2” - Set value for the #2 coin entered.
“AUd” - Program when the signal will sound.
“Err-” - Turn on/off certain errors in control.
“PLSE” - Program the value of the Start
Pulse.
“PLSn” - Program the Start Pulse Input for
one pulse or multiple pulses.
“E Fl” - Fill Error
“CEr-” - Coin Error Parameters
“E dr” - Drain Error
“E Ub” - Unbalance Error (VFD only)
“FILL” - Program fill step options
“LEr-” - Leak Detection
“E oP” - Open Thermistor Error
(Models with Heat)
“E SH” - Shorted Thermistor Error
(Models with Heat)
“LEr1” - Water Leak Detection During
a Machine Cycle
“LEr3” - Number of Cycles between
Leak Detection Test
“AtyP” - Program when control provides an
available output for card and central pay.
“dCYC” - Set the default cycle and
temperature.
“oPL” - Enable/disable OPL Mode in which
no vend price needs to satisfied to operate
machine.
“CyC-” - Program aspects for the various
steps in each type of cycle. There are (8)
cycles available for programming.
(continued)
“SEg1” - Program options for each
segment. There are (8) segments
available for programming
“SgEn” - Segment Enabled/Disabled:
“on” = Enabled
“oFF” = Disabled
“tyPE” - Agitation Type:
1 = Normal
2 = Gentle
“ASPd” - Agitation Speed (VFD only):
“Lo” = Reduced Speed
“rEg” = Normal Speed
“AgIt” - Program the cycles agitation
action and speed
(continued)
“CEr1” - Coin Error
“CEr2” - Coin Error Penalty
““FLEn” - Fill Step Enable/Disable:
“on” = Enabled
“oFF” = Disabled
“FLEU” - Fill Level:
“HI” = High Level
“nEd” = Medium Level
“Lo” = Low Level
“tEnP” - Fill Temperature:
“CoLd” = Cold
“UArn” = Warm
“Hot” = Hot
“E Sd” - Slow Drain Detection Error
“E Ht” - Heat Error (heater only)
“CEr3” - Coin Drops Header Present Error
Page view 18