Programming Control
15
F8237701
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Table 1 (Continued)
Option
Number
Option
Display
Description
Default
Value
Value
Range
e. “SdUr” Supply Duration ** Press START keypad to access options
1. “SEC” Seconds ** 0 - 59
2. “nIn”Minutes ** 0 - 9
e. “AgSt”Agitate Step --
1. “AgEn” Agitate Step Enable/Disable ** on/oFF
2. “AdUr” Agitate Duration (in minutes) ** 1 - 30 for agitate types 1 or 2
3. “HEAt” Heat in Agitate (if heater is present) ** oFF/1/2**
f. “drAn” Drain Step on on/oFF
g. “SPIn” Extract Step --
1. “SPEn” Extract Step Enable/Disable ** on/oFF
2. “SSEC” Extract Seconds ** 0 - 59
3. “SnIn” Extract Minutes ** Intermediate Extract:
Min. Step Time = 30 seconds,
Max. Step Time = 3:59 minutes
Final Extract:
Min. Step Time = 30 seconds,
Max. Step Time = 9:59 minutes
4. “SSPd” Extract Speed (VFD only) ** 1 - 3* (Design 1)
1 - 6* (Design 2)
h. “Cnin”Cycle Time 0* 0-255 minutes
12 “SUPC” Supply/Compartment Dispenser
Programming (Design 1 models only)
C
(Compartment)
C (Compartment)/
S (Supply Dispenser)
13 “bALr” Number of Balance Retries (VFD
only)
Design 1: 3
Design 2: 1
1 - 7
14 “IrA” IR Access (On/Off) on on/oFF
15 “tFC” Fahrenheit/Celsius FAHr
(Fahrenheit)
FAHr (Fahrenheit)/CEL (Celsius)
16 “FH” Hot Water Temperature 140°F (60°C) 35°F-194°F/2°C-90°C
17 “FHC” Warm Water Temperature 100°F (38°C) 35°F-194°F/2°C-90°C
18 “FC” Cold Water Temperature 35°F (2°C) 5°F-194°F/2°C-90°C
19 “Codn” Cooldown Enable/Temperature oFF oFF or 50°F-60°F/10°C-71°C
20 “PtEn” Production Test Cycle (On/Off) on on/oFF
21 “rAEn” Manual Rapid Advance (On/Off) on on/oFF
22 “nCtd” No Cycle Time Display oFF on/oFF
23 “PCtd” Programmable Cycle Time Display oFF on/oFF
24 “SdAd” Slow Drain Detection Adjust 0 0 - 255
25 “SPAU” Pause/Resume Mode oFF on/oFF
*Refer to programming section for value definition.