Programming Control
F8237701
34
How to Program Cycle Segment “SEg1”
There are eight programmable cycle segments. Within
each segment, there are several programmable options.
1. Press the Cold ( ) or the Delicate Cold ( )
keypad to scroll through the eight programmable
Cycle Segments until the desired segment
appears in the display.
2. When the desired segment appears in the display,
press the START (enter) keypad. “SgEn
(Segment Enable/Disable) will appear in the
display.
3. Press the Cold ( ) or the Delicate Cold ( )
keypad to scroll through the Cycle Segment
programmable options.
NOTE: If the Segment Enable/Disable is
programmed “oFF”, the other Cycle Segment
programming options can’t be accessed.
4. Press the START (enter) keypad when the
desired Cycle Segment programmable option
appears in the display.
Programming Segment Enable/Disable
1. When “SgEn” appears in the display, press the
START (enter) keypad. The current Segment
Enable/Disable status will appear in the display.
on = Segment is enabled
oFF”= Segment is disabled
2. Press the Cold ( ) or the Delicate Cold ( )
keypad to change the current status.
NOTE: If the Segment Enable/Disable is
programmed “oFF”, the other Cycle Segment
programming options can’t be accessed.
3. Press the START (enter) keypad when the
desired status appears in the display. The next
Cycle Segment option, “FILL”, will appear in the
display.
NOTE: To program “FILL” (Fill Step), continue to
next Cycle Segment option. To program other
options, press the Cold ( ) or the Delicate Cold ( )
keypad and refer to the appropriate section.
How to Exit Programming Feature
Press the Delicate Warm (<) keypad until the control
returns to Ready Mode.
Programming Fill Step
1. When “FILL” appears in the display, press the
START (enter) keypad. The first Fill step
programming option will appear in the display.
2. Press the Cold ( ) or the Delicate Cold ( )
keypad to scroll through the programmable Fill
step options. Refer to Table 8.
NOTE: Fill Step “FLEn” must be enabled to scroll
through all Fill Step options.
3. Press the START (enter) keypad when the
desired option appears in the display. The current
status will appear in the display. Refer to Table 8.
4. Press the Cold ( ) or the Delicate Cold ( )
keypad to change the current status.
5. Press the START (enter) keypad when the
desired status appears in the display. The next
Fill step option will appear in the display.
NOTE: To program “SUPL” (Supply Step),
continue to next Cycle Segment option. To program
other options, press the Cold ( ) or the Delicate
Cold ( ) keypad and refer to the appropriate
section.
How to Exit Programming Feature
Press the Delicate Warm (<) keypad until the control
returns to Ready Mode.
>
>
>
Fill Step Description Status
FLEn Fill Step
Enable/Disable
on”/“oFF
FLEU Fill Level HI” = high level
nEd” = medium level
Lo” = low level
tEnP Fill Temperature CoLd” = Cold
UArn” = Warm
Hot” = Hot
Table 8
<
<
>