Programming Control
35
F8237701
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Programming Supply Step
1. When “SUPL” appears in the display, press the
START (enter) keypad. The first Supply step
programming option will appear in the display.
2. Press the Cold ( ) or the Delicate Cold ( )
keypad to scroll through the programmable
Supply step options. Refer to Table 9.
NOTE: Supply Step “SUEn” must be enabled to
scroll through all Supply Step options.
3. Press the START (enter) keypad when the
desired option appears in the display. The current
status value will appear in the display. Refer to
Table 9.
NOTE: For the Dispenser options, the display will
show “Cx” or “Sx” depending whether or not the
control is programmed as compartment-oriented
or supply-oriented. Refer to option 12, Supply/
Compartment Dispenser Programming.
4. Press the Cold ( ) or the Delicate Cold ( )
keypad to change the current status/value.
5. Press the START (enter) keypad when the
desired status/value appears in the display. The
next Supply step option will appear in the
display.
NOTE: To program “AgSt” (Agitate Step),
continue to next Cycle Segment option. If in the
Dispenser Options or Supply Duration
programming option, press the Delicate Warm (<)
keypad first. To program other options, press the
Cold ( ) or the Delicate Cold ( ) keypad and refer
to the appropriate section.
How to Exit Programming Feature
Press the Delicate Warm (<) keypad until the control
returns to Ready Mode.
Supply Step Description Status/Value
“SUEn” Supply Step
Enable/Disable
“on”/“oFF”
“diSP” Dispenser options
(Design 1 Models only)
Press START (enter)
to access options
“C2” or
“S1”
Compartment 2/
Supply #1
“on”/“oFF”
“C3” or
“S2”
Compartment 3/
Supply #2
“on”/“oFF”
“C4” or
“S3”
Compartment 4/
Supply #3
“on”/“oFF”
“S4” Supply #4 “on”/“oFF”
Dispenser options
(Design 2 Models only)
Press START (enter)
to access options
“C2” Compartment 2 “on”/“oFF”
“C3” Compartment 3 “on”/“oFF”
“C4” Compartment 4 “on”/“oFF”
“S1” Supply #1 “on”/“oFF”
“S2” Supply #2 “on”/“oFF”
“S3” Supply #3 “on”/“oFF”
“S4” Supply #4 “on”/“oFF”
“SdUr” Supply Duration Press START (enter)
to access options
“SEC” Seconds 0-59
“nIn” Minutes 0-9
Table 9