Page view 55
F8237701
54
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Error Codes
Following is a list of possible error codes for an
electronic control. Errors beginning with “EI” refer to
external device Infra-red communication errors. All
other errors refer to machine errors.
Display Description
Cause/
Corrective Action
EI01
Transmission Failure Communication failure. Re-aim external device and try
again.
EI02
Time-out Error Communication failure. Re-aim external device and try
again.
EI03
Invalid Command Code Communication successful, but the command was not
valid for this machine type, or the control could not
perform the command in its current mode of operation.
Ensure data is for current machine type and control is in
correct mode.
EI04
Expecting Upload Request Communication failure. Re-aim external device and try
again.
EI05
Invalid or Out-of-Range Data The value in at least one of the programming options is
invalid or out of range. Recheck the programming
option’s value and try again.
EI09
CRC-16 Error Communication failure. Re-aim external device and try
again.
EI0A
Framing Error Communication error. Re-aim external device and try
again.
EI0C
Time-out Exceeded Communication error. Re-aim external device and try
again.
EI0E
Encryption Error Communication error. Re-aim external device and try
again. If the problem persists, check that the security
code is correct.
EI0F
Infra-red Disabled Communication failure or infra-red is disabled.
Manually enable infra-red on control or re-aim external
device and try again.
E FL
Fill Error Programmed water level not reached within 10 minutes
(or other programmed length of time) in any fill agitate
cycle. End cycle. Power down machine to clear.
E SP
SPI Communications Error Front End control cannot communicate with output
board. Power down the machine, power up and try
again.
E dL
Door Lock Error Door does not lock immeadiately upon closing (open
and reclose door) or doesn’t unlock 5 seconds after cycle
completion. Power down machine and retry.
Table 17 (continued)
Page view 55
1 2 ... 51 52 53 54 55 56 57 58 59 60 61 ... 69 70

Comments to this Manuals

No comments

LUXA2 TX-P1 manuály

Uživatelské manuály a uživatelské příručky pro Energetické banky LUXA2 TX-P1.
Poskytujeme 1 manuály pdf LUXA2 TX-P1 ke stažení zdarma podle typů dokumentů: Uživatelský manuál


Luxa2 TX-P1 Uživatelský manuál (2 strany)


Značka: Luxa2 | Kategorie: Power banks | Velikost: 4.13 MB |

 

Tabulka s obsahem





Další produkty a příručky pro Energetické banky LUXA2

Modely Typ Dokumentu
Žádný