LED OPL and UniLinc Troubleshooting
Troubleshooting the Moisture Sensor Circuit
NOTE: Troubleshooting must be done with the machine basket empty.
52.Troubleshooting at the Control
1. On the control board, unplug the harness from header H5 (Refer to Figure 9).
2. Insert ohm meter probes into pins 1 and 2 of the harness. If the metered value is infinite resistance, open load
(OL), proceed to step 3. If not, proceed to Paragraph 53.
3. Create a direct short between machine basket and moisture sensing baffle/ground using test jumper
(Refer to Figure 10). If metered value is less than 1 ohm, circuit is functioning properly; double-check
machine configuration and cycle programming. If 1 ohm or greater, proceed to Paragraph 53.
TMB2396S
1 H5
2 Harness
Figure 9
To reduce the risk of electric shock, fire, explosion, serious injury or death:
Disconnect electric power to the tumble dryer before servicing.
Close gas shut-off valve to gas tumble dryer before servicing.
Close steam valve to steam tumble dryer before servicing.
Never start the tumble dryer with any guards/panels removed.
Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the tumble dryer is properly grounded.
W002R1
WARNING