Alliance Laundry Systems BU170S Service Manual Page 33

  • Download
  • Add to my manuals
  • Print
  • Page
    / 120
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 32
70422201R1
31
Troubleshooting
18.Tumble Dryer Will Not Start, Time On Drying Timer, Door Closed
TMB2367S
Tumbler will
not start, time
on drying timer,
door closed.
Is there line
voltage into
transformer?
Check
electrical
service to
tumbler
(fuses/circuit
breaker).
Is there control (24
VAC) voltage out
of transformer?
Replace
transformer.
Is there a
blown control
circuit fuse?
Replace fuse.
Is there 24
volts into door
switch?
Check for broken
wire between fuse
and door switch.
Is there 24
volts out of
door switch?
Is door switch
functioning
properly?
Replace door
switch.
Is there 24
volts into lint
panel switch?
Check for
broken wire
between fuse
and lint panel
switch.
Is there 24 volts
out of lint panel
switch?
Is lint panel
switch
functioning
properly?
Replace or
adjust lint
panel switch.
No
Yes
(1)
(3)
(4)
(2)
No
Yes
Yes
No
No
Yes
No
No
Yes
No
Yes
No
Yes
No
Is there 24
volts across
fan contactor
coil?
Check for
broken wire or
poor
connection at
harness plug.
Replace fan
contactor.
No
Ye s
Page view 32
1 2 ... 28 29 30 31 32 33 34 35 36 37 38 ... 119 120

Comments to this Manuals

No comments