Troubleshooting
9. Burner Shuts off Prematurely
Burner shuts
off prematurely
Is there improper or
inadequate exhaust and/or
make-up air?
Refer to Installation
Manual for exhaust
and make-up air
requirements.
Is tumbler not properly
equipped for type of gas
used or altitude?
Tumbler is equipped for type of
gas specified on serial plate. If
not properly equipped for gas
type and altitude, obtain and
install correct components.
Is burner flame
improperly adjusted?
Refer to Adjustments Section
for burner flame adjustment.
Is high limit thermostat
cycling off?
Refer to Paragraph 8.
Ye s
No
Ye s
No
Ye s
No
Ye s
No
TMB2364S
Is fan rotation improper?
May be due to improper
wiring resulting in low
airflow. Refer to
Installation Manual..
Are gas valve coils inoperative?
Test coils and replace if
inoperative.
Ye s
No
Ye s