On Premise Micro Control (RM) Troubleshooting
41.Motor Will Not Start/Run
Motor Will Not
Start/Run
Is there
voltage between
H2-7 and H3-4?
Is there
24 VAC across
the coil of the motor
control relay?
Yes
Replace
control.
No
Correct wiring
to coil of
motor relay .
No
TMB2370S
Yes
Gas and steam heat.
Three phase power supply.
(1)
(2)
Note: For high voltage three
phase supply (200 volts or
higher), the motor is
supplied by L1, L2,
L3 through the motor
contactor terminals T1,
T2, T3. Make the appropriate
adjustments when doing
voltage checks.
Is there
supply voltage
between L1-L2, L2-L3
and L1-L3
of motor?
Replace
motor.
Correct wiring
between motor
and motor
contactor.
No
No
Yes
(5)
Is there
supply voltage
at L1-L2, L2-L3 and
L1-L3 at the motor
contactor?
(3)
Correct wiring
between L1, L2,
L3 and power
supply.
Is there
supply voltage
across T1-T2, T2-T3
and T1-T3 on the
motor contactor?
No
Yes
Replace motor
control relay.
(4)
Yes
Note: Test conducted with vend
price satisfied and start button
pressed.
Page view 69