70422201R1
83
LED OPL and UniLinc Troubleshooting
47.No Display
Is there 24 volts AC
at H1-1 to H1-3
Is there 24 volts AC
at H1-2 to H1-4?
Check Transformer
and Fuse F4.
Replace
I/O Board (AP1).
Replace or
repair harness.
No
Yes
Yes
Yes
Yes
No
TMB2377S
NOTE: On the UniLinc LCD-equipped machines, verify the contrast is set correctly prior to troubleshooting.
Is there 24 volts AC at
H8-1 to H8-3?
No
No
Is there 24 volts DC
at H3-13 to H3-11, closest
to the front-end control
(AP2?)
(1)
(2)
(3)
(4a)
CAUTION: Always power down the machine
PRIOR to disconnecting or connecting the
H3 harness. Once disconnected, you can
power up the machine for troubleshooting.
Failure to do so may damage the front-end control.
NOTE: The following checks are DC
voltage checks.
NOTE: The pins H1-2 and H1-4 on I/O Board that connect
to pins H8-1 and H8-3 on the front-end control only provide
24 volts AC to the front-end control's network circuitry.
Yes
No
Is there 29 - 33 volts DC
at H3-14 to H3-11?
Yes
No
Is there 5 volts DC at
H3-12 to H3-11?
(4b)
Replace
front-end control (AP2.)
(4c)
NOTE: If the voltage is present but
lower than 24 volts AC, ensure the
correct transformer configuration
jumper is installed.
Verify correct transformer
configuration jumper is
installed. Check harness
and I/O Board (AP1).
Replace as necessary.
Comments to this Manuals