LED OPL and UniLinc Troubleshooting
64.Diagnostic Testing
Models with RU Control Suffix
Diagnostic Menu
The Diagnostic Menu contains Test, Alarm and
Machine ID Menus. The menus contain specific
diagnostic information and manufacturing data for the
machine. The , , and keypads
position the highlighted box. Press the keypad to
select the menu choice.
Press the keypad while in the Diagnostic Menu
to return to System Menu.
Test Menu
The Test Menu provides features for manufacturing
and customer service testing. The highlighted box is
moved horizontally and vertically using the
and keypads. Press the
keypad to select the menu choice.
Press the keypad to return to Diagnostic Menu.
The screen will display “Diagnostics Are Disabled” if
the manual diagnostics have been programmed off.
Diagnostic test commands via PDA and network will
still function.
Test Cycle Menu
The Test Cycle Menu is used to run several test steps
as well as a ten-minute cycle. Step 01 keypad test
requires the user to press each keypad. Step 02 Door
Status shows whether the loading and lint doors are
open or closed. Press any key to advance. Step 03
Screen Test shows four screens that test the LCD
screen. Press any key to advance through each of the
four test steps.
The Test Cycle Menu for Test Steps 4-13 is shown in
Figure 16.
It is similar to the Inputs/Outputs Menu except that the
test step is shown at the bottom of the display and a
key press prompt message is shown in the lower right
corner. Press to advance through the steps. Refer
to Table 7 for more details of each step. Press to
terminate the test.
TMB1325R
Figure 14
TMB1326R
Figure 15
TMB1325R
Machine ID
Test
Diagnostic Menu
Alarms
TMB1326R
Test Cycle
Test Menu
Inputs and
Outputs
Diagnostics Are Disabled
TMB1424R
Figure 16
Test Cycle
Outputs:
Intputs:
RPM:0Temp:90 F
Step04: Temp Index - 50, 75 -170 (12)
Moisture:1%
PRESS
DM FM FW RV HT EA IR
DR LD AFS FCRS FCLS CL SL1 SL2 IL
RS DIP1 DIP2 DIP3 DIP4 DIP5 DIP6 DIP7 DIP8