LED OPL and UniLinc Troubleshooting
45.No Drive Motor Rotation
Is there 24 volts AC at
H6-1 to H6-9?
Is there 24 volts AC at
H6-7 to H6-10 (F)
or H6-6 to H6-10 (R)?
Check Transformer
and Fuse F3.
Replace or
repair harness.
No
Yes
Yes
Yes
Yes
Yes
Yes
No
No
TMB2375S
NOTE: This is for machines with the reversing option only. Each step has a F (Forward) or R (Reverse) representing
the direction of rotation. Ensure the cycle is programmed for either reversing or non-reversing.
NOTE: All mechanical checks should be performed prior to starting the electrical checks. Ensure the belt(s), basket,
idler and pulleys are rotating freely.
Is there 24 VAC at
contactor A1 to A2
(F - Pink to White;
R - Pink/Black to White)?
Is there 5 volts
DC at H3-3 to H3-11 (F) or
H3-2 to H3-11 (R) with
contactor commanded to close
and 0 volts DC with
contactor not
commanded?
Check control harness
H3 and front-end control (AP2).
Replace as required.
Check control harness
H3 and I/O board (AP1).
Replace as required.
NOTE: The following checks are DC voltage checks.
CAUTION: Always power down the machine PRIOR to
disconnecting or connecting the H3 harness. Once
harness is disconnected, you can power up the machine
for troubleshooting. Failure to do so may damage
the front-end control.
NOTE: The H3 harness will need to remain
connected during this test.
No
Replace contactor.
Is there line voltage
on the motor side
of the contactor?
No
Replace contactor.
No
Check incoming
power and wiring.
Replace or repair
as required.
No
Is contactor
energizing?
NOTE: The following checks are AC voltage
checks and should be equal to the line voltage
of the machine. Refer to the serial plate of the
machine for correct line voltage. The machine’s
motor(s) may be single or three phase.
Is there line voltage
on the line side of
both contactors?
Yes
Repair or replace
wiring harness.
Replace motor.
No
Yes
Is there line voltage
at the motor?
(1)
(2)
(4)
(3)
(5)
(6)
(7)
NOTE: If the voltage is present but
lower than 24 volts AC, ensure the
correct transformer configuration
jumper is installed.