Alliance Laundry Systems BU170S Service Manual Page 14

  • Download
  • Add to my manuals
  • Print
  • Page
    / 120
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 13
12
70422201R1
Introduction
Modes of Operation
Power-Up Mode
Sends power to control, begins a status check
of the system. Can send control into Idle Mode
or Lockout Mode.
Idle Mode
Machine is operable while it monitors
temperature sensor readings. Control will enter
Power Disconnect Mode if temperature
trip-point is exceeded.
Power Disconnect Mode
Machine is disabled and controls on front will not
operate, will enter Power Disconnect Mode for one
second, then Water On Mode.
Water On Mode
Machine is disabled and controls on front will not operate. Remain in this mode
for 90 seconds, then enter Lockout Mode. Can enter Lockout Error Mode if both
temperature sensors become open, which occurs when temperature is below
40° F (4° C). Will enter Idle Mode if reset button is pressed. Refer to
Figure 2.
Lockout Mode
Machine is disabled and controls on front will not
operate. Control monitors temperature readings. Enters
Water On Mode if temperature trip-point is exceeded.
Will enter Idle Mode if reset button is pressed.
Lockout Error Mode
Machine is disabled and controls on front will not
operate. Water dispenses for four minutes. When the
reset button is press ed, the control enters Idle
Mode.
If temperature
trip-point exceeded
If both temperature
sensors become open
When reset
button is pressed
If reset but ton
is pressed
Page view 13
1 2 ... 9 10 11 12 13 14 15 16 17 18 19 ... 119 120

Comments to this Manuals

No comments