Hybrid Timer Control Troubleshooting
38.Error Codes
Display Definition Corrective Action
OP
Open thermistor error. Check thermistor. Replace if inoperative.
Check wiring between control and
thermistor. Refer to wiring diagram for
proper wiring.
Check control. Replace if inoperative.
SH
Shorted thermistor error. Check thermistor. Replace if inoperative.
Check wiring between control and
thermistor. Refer to wiring diagram for
proper wiring.
Check control. Replace if inoperative.
AF-1
Airflow switch closed when cycle started. Check airflow switch. Replace if
inoperative.
AF-2
Airflow switch failed to closed after cycle
started.
Check airflow switch. Replace if
inoperative.
AF (flashing)
Airflow switch opened/closed 5 or more
times in a running cycle.
Check airflow switch. Replace if
inoperative.
To reduce the risk of electric shock, fire, explosion, serious injury or death:
Disconnect electric power to the tumbler before servicing.
Close gas shut-off valve to gas tumbler before servicing.
Close steam valve to steam tumbler before servicing.
Never start the tumbler with any guards/panels removed.
Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the tumbler is properly grounded.