Hybrid Timer Control Troubleshooting
38.Error Codes
Display Definition Corrective Action
OP
Open thermistor error. • Check thermistor. Replace if inoperative.
• Check wiring between control and
thermistor. Refer to wiring diagram for
proper wiring.
• Check control. Replace if inoperative.
SH
Shorted thermistor error. • Check thermistor. Replace if inoperative.
• Check wiring between control and
thermistor. Refer to wiring diagram for
proper wiring.
• Check control. Replace if inoperative.
AF-1
Airflow switch closed when cycle started. • Check airflow switch. Replace if
inoperative.
AF-2
Airflow switch failed to closed after cycle
started.
• Check airflow switch. Replace if
inoperative.
AF (flashing)
Airflow switch opened/closed 5 or more
times in a running cycle.
• Check airflow switch. Replace if
inoperative.
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the tumbler before servicing.
• Close gas shut-off valve to gas tumbler before servicing.
• Close steam valve to steam tumbler before servicing.
• Never start the tumbler with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the tumbler is properly grounded.