LED OPL and UniLinc Troubleshooting
60.Shorted or Open Thermistor
UniLinc Error Display: Shorted Thermistor
Open Thermistor
LED OPL Error Display: ESH
EoP
No
Yes
(1)
NOTE: This resistance will vary with cabinet air temperature:
the higher the temperature, the lower the resistance.
Replace front-end
control (AP2).
Is there approximately
50k ohms of resistance at 77°F
across H7-1 and H7-2?
Check each wire for possible
ground fault. Replace temperature
sensor and/or harness.
TMB2393S