LED OPL and UniLinc Troubleshooting
46.Stove and Cabinet Limit Errors
UniLinc Error Display: Stove and Cabinet Limit Errors
LED OPL Error Display: E Cab
E SL
E SL2
NOTE: The machine must currently be trying to heat with airflow switch closed, fan motor contactor
engaged and fan motor centrifugal switch closed before checking the status of the cabinet, stove and stove 2
limits.
Is there 24 volts AC at
H6-1 to H6-9?
Is there 24 volts AC st
H2-9 to H6-9?
Check Transformer
and Fuse F3.
Replace
I/O Board (AP1).
Replace
I/O Board (AP1).
Replace
I/O Board (AP1).
Check harness and
cabinet limit switch.
Repair or replace
as required.
No
Yes
Yes
Yes
Yes
Yes
No
TMB2376S
NOTE: Not all machines have the stove limit or the secondary stove limit switch. Please refer to your machine’s
wiring diagram. Also, some machines have manual reset thermostats; these must be reset prior to attempting the
troubleshooting procedures.
Is there 24 volts AC at
H2-2 to H6-9?
No
Is there 24 volts AC at
H2-7 to H6-9?
No
No
Check harness and
stove limit switch.
Repair or replace
as required.
No
Is there 24 volts AC at
H2-8 to H6-9?
Is there 24 volts AC at
H2-1 to H6-9?
Yes
Check harness and
secondary stove
limit switch. Repair
or replace as required.
No
Yes
Yes
Check control harness
H3. Replace harness
or I/O Board (AP1)
as required.
Check control harness
H3. Replace harness
or I/O Board (AP1)
as required.
Check control harness
H3. Replace harness
or I/O Board (AP1)
as required.
No
Yes
Is there 24 volts AC at
H2-11 to H6-9?
(1)
(2)
(3)
(5)
(6)
(7)
Is there 5 volts DC at
H3-9 to H3-11 with cabinet
limit circuit open and 0 volts
DC with switch closed?
No
Is there 5 volts DC
at H3-20 to H3-11 with stove
limit circuit open and 0 volts
DC with switch closed?
(8)
(4)
NOTE: Steam model machines will
utilize a jumper from pins H2-8 to H2-1.
NOTE: You will need to manually open
the circuit.
CAUTION: Always power down the machine
PRIOR to disconnecting or connecting the
H3 harness. Once disconnected, you can
power up the machine for troubleshooting.
Failure to do so may damage the front-end
control.
NOTE: The following checks are DC
Voltage checks.
NOTE: You will need to manually open
the circuit.
(9)
Is there 5 volts DC at
H3-10 to H3-11 with
secondary stove limit circuit
open and 0 volts DC with
switch closed?
Yes
No
Replace front-end
control (AP2).
(10)
NOTE: The machine must currently be trying to heat with airflow switch closed, fan motor contactor engaged
and fan motor centrifigal switch closed before checking the status of the cabinet, cabinet store and store 2 limits.
NOTE: If the voltage is present but
lower than 24 volts AC, ensure the
correct transformer configuration
jumper is installed.