Alliance Laundry Systems BU170S Service Manual Page 20

  • Download
  • Add to my manuals
  • Print
  • Page
    / 120
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 19
18
70422201R1
Troubleshooting
5. No Heat Condition (Non-CE and Non-Australian Models)
Ignition Control Module Function
There are four components to the ignition system: the
module, the spark igniter, the high voltage cable and
ground wire. When 24 VAC is applied between the TH
and GND terminals on the module, the module will
send the high voltage signal to the igniter and 24 VAC
to the gas valve coils. Gas will hit the sparking igniter
and flame will be established. The igniter being
engulfed in flame will create a millivolt electric signal
that is sent back to the module by the high voltage
cable; this is what the module sees as flame
recognition. If the millivolt signal is not at the module
in ten seconds, the module will go into safety lockout.
The voltage will be cut from the igniter and gas valve
coils and will not be restored until voltage is cycled at
the module.
Intermittent Heat Test Procedure
On ignition control modules with date codes higher
than 08t2, perform the following test.
Start the tumble dryer and run for 10 minutes (verify
that the tumble dryer is heating properly). After the 10
minute cycle, re-start the tumble dryer and once again
verify the unit is heating. Repeat this procedure 3
times. If the tumble dryer passes this test, the ignition
control module is operating properly and SHOULD
NOT be changed. Refer to Troubleshooting Manual
for additional service procedures.
To reduce the risk of electric shock, fire, explosion, serious injury or death:
Disconnect electric power to the tumble dryer before servicing.
Close gas shut-off valve to gas tumble dryer before servicing.
Close steam valve to steam tumble dryer before servicing.
Never start the tumble dryer with any guards/panels removed.
Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the tumble dryer is properly grounded.