Alliance Laundry Systems BU170S Service Manual Page 16

  • Download
  • Add to my manuals
  • Print
  • Page
    / 120
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 15
14
70422201R1
Troubleshooting
1. Motor Does Not Start
TMB2360S
Motor does
not start
Is electrical power
off, has circuit
breaker tripped or
has control fuse
blown?
Check service
to tumbler.
Check primary
and secondary
fuses.
Is transformer
inoperative?
Replace
transformer.
Is loading door
open or is door
switch
inoperative?
Close door or
test switch and
replace if
inoperative.
Is lint panel
switch not
closing?
Test lint panel
switch, replace
if inoperative.
Are trunnion
bearings
binding?
Replace
trunnion
bearings.
Is there
broken, loose
or incorrect
wiring?
Refer to wiring
diagram
located on
back of tumbler
or in literature
packet.
Ye s
No
Ye s
No
Ye s
No
Ye s
Ye s
No
Ye s
Are idler
bearings
binding?
Replace
bearings.
Is motor
inoperative?
Have motor
tested and
replace if
inoperative.
Ye s
No
No
Ye s
No
TMB2360S
Page view 15
1 2 ... 11 12 13 14 15 16 17 18 19 20 21 ... 119 120