  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 20
70422201R1
19
Troubleshooting
6. No Heat Condition
Is the Ignition Control
Module’s red light on?
No
No
Yes
Yes
Refer to
Paragraph 7.
Replace igniter and high
voltage lead. Retest unit. If
unit still does not spark,
replace module.
No
Refer to Paragraph 7
for heat circuit
troubleshooting.
Is there
24 volts AC between
the TH and GND terminals
on the module?
Yes
No
Check wiring between
gas valve and module.
If wiring is good,
replace module.
Yes
Yes
Is there continuity
between GND terminal on
module and machine?
No No
Does the igniter
spark but no
flame is produced?
No
Yes
Is there
24 volts AC at the gas
valve coils when igniter
is sparking?
Is the igniter
positioned properly
in the flame, and does the
flame look good?
Does the igniter
spark?
Verify that gas is supplied
to the machine. If gas and
voltage are present,
replace gas valve or coils.
Does the flame turn
off after igniter
stops sparking?
No
Yes
Replace module.
Adjust position of
igniter and retest.
Yes
Verify machine is
properly grounded.
Replace igniter and
high voltage lead.
Retest unit. If it still
does not sense flame,
replace module.
TMB2395S