70422201R1
LED OPL and UniLinc Troubleshooting
3. Connect one ohm meter probe to the connector in the basket shaft (Refer to Figure 13).
4. Connect the other ohm meter probe to one of the gray wire harness terminals on the back end of the machine
basket. If the metered value is less than 1 ohm, proceed to Step 5. If 1 ohm or greater, replace harness and
return to Paragraph 52.
5. Connect one ohm meter probe to the connector in the basket shaft.
6. Connect the other ohm meter probe to the other gray wire harness terminal on the back end of the machine
basket. If the metered value is less than 1 ohm, proceed to Step 7. If 1 ohm or greater, replace harness and
return to Paragraph 52.
7. Connect one ohm meter probe to the connector in the basket shaft.
8. Connect the other ohm meter probe to one of the moisture sensing baffles (refer to Figure 10). If the metered
value is less than 1 ohm, proceed to Step 9. If 1 ohm or greater, proceed to Paragraph 57.
9. Connect one ohm meter probe to the connector in the basket shaft.
10. Connect the other ohm meter probe to the other moisture sensing baffle. If the metered value is less than 1
ohm, circuit is functioning properly; double-check machine configuration and cycle programming. If 1 ohm
or greater, proceed to Paragraph 57.
57.Troubleshooting at the Moisture Sensing Baffles with Machine Basket
Removed
1. Disassemble moisture sensing baffle and inspect for lint buildup and foreign objects. Verify wire harness
connections.
2. Disassemble other moisture sensing baffle and inspect for lint buildup and foreign objects. Verify wire
harness connections.
3. Double-check machine configuration and cycle programming.