LED OPL and UniLinc Troubleshooting
48.Airflow Errors
UniLinc Error Display: Airflow Switch Sensed Closed While Not In Run Mode
Airflow Switch Does Not Close After Cycle Started
Airflow Switch Bounces During A Running Cycle
LED OPL Error Display: E AF1
E AF2
E AF
Is there 24 volts AC
at H6-1 to H6-9?
Is there 24 volts AC
at H2-12 to H6-9?
Check Transformer
and Fuse F3.
Replace
I/O Board (AP1).
No
Yes
Yes
Yes
Yes
No
No
Check control harness
H3 and I/O Board (AP1).
Replace as required.
No
Is there 5 volts DC at H3-7
to H3-11 with switch open
and 0 volts DC with
switch closed?
(1)
(2)
(3)
(4)
CAUTION: Always power down the machine
PRIOR to disconnecting or connecting the
H3 harness. Once disconnected, you can
power up the machine for troubleshooting.
Failure to do so may damage the front-end control.
NOTE: The following checks are DC
voltage checks.
Replace front-end
control (AP2).
NOTE: Check airflow switch for proper mechanical operation; ensure there is no lint or other items interfering
with the proper operation.
NOTE: The airflow switch is required to be open prior to the beginning of the cycle. The switch is also required
to close within the cycle.
NOTE: If the voltage is present but
lower than 24 volts AC, ensure the
correct transformer configuration
jumper is installed.
Check harness and
airflow switch.
Repair or replace
as required.
Is there 24 volts AC at
H2-5 to H6-9 with airflow
switch closed?
TMB2378S