Programming Control
F8238301
52
23. No Cycle Time Display “nCtd”
This option allows the owner to enable or disable
whether the cycle time will appear in the display.
How to Program No Cycle Time Display
1. Control must be in Manual Mode. Refer to
Entering the Manual Mode.
2. Press the NORMAL/40C ( ) or the PERM
PRESS/40C ( ) keypad until “Prog” appears in
the display. Press the START (enter) keypad and
AtS1” will appear in the display.
3. Press the NORMAL/40C ( ) or the PERM
PRESS/40C ( ) keypad to scroll through the
programmable options until “nCtd” appears in
the display.
4. When “nCtd” appears in the display, press the
START (enter) keypad. The current No Cycle
Time Display status will appear in the display.
on = Option Enabled (Default Setting)
oFF” = Option Disabled
5. Press the NORMAL/40C ( ) or the PERM
PRESS/40C ( ) keypad to change the current
status.
6. Press the START (enter) keypad when the
desired status appears in the display. The next
option, “PCtd”, will appear in the display.
NOTE: To program “PCtd” (Programmable Cycle
Time Display), refer to option 24. To program other
options, refer to the appropriate section.
How to Exit Programming Feature
Press the PERM PRESS/60C (<) keypad until the
control returns to Ready Mode.
24. Programmable Cycle Time
Display “PCtd”
This option allows the owner to program the displayed
cycle time.
How to Program Programmable Cycle
Time Display
1. Control must be in Manual Mode. Refer to
Entering the Manual Mode.
2. Press the NORMAL/40C ( ) or the PERM
PRESS/40C ( ) keypad until “Prog” appears in
the display. Press the START (enter) keypad and
AtS1” will appear in the display.
3. Press the NORMAL/40C ( ) or the PERM
PRESS/40C ( ) keypad to scroll through the
programmable options until “PCtd” appears in
the display.
4. When “PCtd” appears in the display, press the
START (enter) keypad. The current
Programmable Cycle Time Display status will
appear in the display.
on = Option Enabled
oFF” = Option Disabled (Default Setting)
NOTE: Enabling this option will not change the
cycle time, only the display time for the user. Refer
to option “Cnin” in Cycle Programming to
program minutes to the cycle time display.
5. Press the NORMAL/40C ( ) or the PERM
PRESS/40C ( ) keypad to change the current
status.
6. Press the START (enter) keypad when the
desired status appears in the display. The next
option, “SdAd”, will appear in the display.
NOTE: To program “SdAd” (Slow Drain
Detection Adjust Value), refer to option 25. To
program other options, refer to the appropriate
section.
How to Exit Programming Feature