Alliance Laundry Systems SCU020JLF Instruction Manual Page 47

  • Download
  • Add to my manuals
  • Print
  • Page
    / 109
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 46
Programming Control
45
F8238301
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Programming Extract Step
1. When “SPIn” appears in the display, press the
START (enter) keypad. The first Extract step
programming option will appear in the display.
2. Press the NORMAL/40C ( ) or the PERM
PRESS/40C ( ) keypad to scroll through the
programmable Extract step options. Refer to
Table 12.
NOTE: Extract Step “SPEn” must be enabled to
scroll through all Extract Step options.
3. Press the START (enter) keypad when the
desired option appears in the display. The current
status/value will appear in the display. Refer to
Table 12.
4. Press the NORMAL/40C ( ) or the PERM
PRESS/40C ( ) keypad to change the current
status/value.
5. Press the START (enter) keypad when the
desired status/value appears in the display. The
next Cycle Segment step option, “SEg2” will
appear in the display.
NOTE: To program “Cnin” (Cycle Time), continue
to next Cycle Segment option. To program other
options press the NORMAL/40C ( ) or the PERM
PRESS/40C ( ) keypads and refer to the
appropriate section.
How to Exit Programming Feature
Press the PERM PRESS/60C (<) keypad until the
control returns to Ready Mode.
Extract
Step
Description Status/Value
SPEn Extract Step
Enable/Disable
on”/“oFF
SSEC Extract Seconds 0-59
SnIn Extract Minutes Intermediate Extract:
minimum step time =
30 seconds
maximum step time =
3:59 minutes
Final Extract:
minimum step time =
30 seconds
maximum step time =
9:59 minutes
SSPd Extract Speed*
(G) (Design 1-
VFD only)
1 = very low speed (80)
2 = low speed (80)
3 = medium speed (100)
4 = high speed (120)
5 = very high speed (140)
Extract Speed*
(G) (Design 2-
VFD only)
1 = very low speed (27)
2 = low speed (80)
3 = medium speed (100)
4 = high speed (125)
5 = very high speed (150)
6 = ultra high speed (200)
*F-speed machines use speeds 1-3.
Table 12
<
>
<
>
<
Page view 46
1 2 ... 42 43 44 45 46 47 48 49 50 51 52 ... 108 109

Comments to this Manuals

No comments