Page view 44
Programming Control
43
F8238301
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Programming Supply Step
1. When “SUPL” appears in the display, press the
START (enter) keypad. The first Supply step
programming option will appear in the display.
2. Press the NORMAL/40C ( ) or the PERM
PRESS/40C ( ) keypad to scroll through the
programmable Supply step options. Refer to
Table 10.
NOTE: Supply Step “SUEn” must be enabled to
scroll through all Supply Step options.
3. Press the START (enter) keypad when the
desired option appears in the display. The current
status value will appear in the display. Refer to
Table 10.
NOTE: For the Dispenser options, the display will
show “Cx” or “Sx” depending whether or not the
control is programmed as compartment-oriented
or supply-oriented. Refer to option Supply/
Compartment Dispenser Programming.
4. Press the NORMAL/40C ( ) or the PERM
PRESS/40C ( ) keypad to change the current
status/value.
5. Press the START (enter) keypad when the
desired status/value appears in the display. The
next Supply step option will appear in the
display.
NOTE: To program “AgSt” (Agitate Step),
continue to next Cycle Segment option. If in the
Dispenser Options or Supply Duration
programming option, press the PERM PRESS/60C
(<) keypad first. To program other options, press
the NORMAL/40C ( ) or the PERM PRESS/40C
( ) keypads and refer to the appropriate section.
How to Exit Programming Feature
Press the PERM PRESS/60C (<) keypad until the
control returns to Ready Mode.
Supply Step Description Status/Value
SUEn Supply Step
Enable/Disable
on”/“oFF
diSP Dispenser options
(Design 1 Models only)
Press START (enter)
to access options
C2” or
S1
Compartment 2/
Supply #1
on”/“oFF
C3” or
S2
Compartment 3/
Supply #2
on”/“oFF
C4” or
S3
Compartment 4/
Supply #3
on”/“oFF
S4 Supply #4 on”/“oFF
Dispenser options
(Design 2 Models only)
Press START (enter)
to access options
C2 Compartment 2 on”/“oFF
C3 Compartment 3 on”/“oFF
C4 Compartment 4 on”/“oFF
S1 Supply #1 on”/“oFF
S2 Supply #2 on”/“oFF
S3 Supply #3 on”/“oFF
S4 Supply #4 on”/“oFF
SdUr Supply Duration Press START (enter)
to access options
SEC Seconds 0-59
nIn Minutes 0-9
Table 10
<
>
<
>
<