Programming Control
What Can Be Programmed?
This feature allows the owner to program cycle
information, standard vend pricing, special vends and
other features by using the keypads. The control must
have the Manual Programming Mode enabled, which
is the factory default. This mode can only be turned
“OFFandON” by using an external device. Refer to
this section when programming the control.
This section offers a detailed description of all available
programmable options.
Each description includes instructions on when and
why the option might be used and, more importantly,
how to program the option.
For more advanced users, a quick reference list of the
options available through the programming mode and
programming flowcharts are located on the following
pages.
NOTE: The letters and numbers in the Option
Display column of the Programmable Options
Available list are what will be shown in the display
when that option is selected.
Programmable Options Available
Option
Number
Option
Display
Description Default Value Value Range
1“AtS1 Normal/90C Vend Price 200 0 - 65535
2“dEn1 Coin #1 Value 25 1 - 65535
3“dEn2 Coin #2 Value 100 1 - 65535
4“PLSE Start Pulse Value 25 1 - 65535
5“PLSn Start Pulse Mode 128 oFF/128/192
6“AtyP Available Type 00 - 3
7“dCYC Default Cycle 5* 1-9*
8“oPL OPL Mode Enable/Disable oFF on/oFF
9“AUd”Audio Signal 29* 0-31*
10 CArd Card Reader Display Control oFF on/oFF
11 Err- Errors --
a. CEr- Coin Error Parameters --
1. CEr1 Coin Error on on/oFF
2. CEr2 Coin Error Penalty oFF on/oFF
3. CEr3 Coin Drops Header Present Error on on/oFF
b. EFL Fill Errors on on/oFF
c. Edr”Drain Error on on/oFF
d. EUb Unbalance Error Display on on/oFF
e. EoP Open Thermister Error Display on on/oFF
f. ESH Shorted Thermistor Error Display on on/oFF
g. EHt Heat Error Display (Heater only) on on/oFF
*Refer to programming section for value definition.
**Refer to the Cycle Chart for default cycle setting information.
Table 1 (continued)