Testing Machine and Electronic Control Functions
F8238301
90
Production Test Cycle Quick Reference Chart
Display Test Cycle Step Comments
S xx FEC Control Software
Ver s ion
xx is the software version number.
o xx Output Board Software
Ver s ion
xx is the software version number.
Ct25 Control Type 2.5 is the Control type.
COIn Control Type Coin
IntL Control Type International
drAn Drain Type Gravity Drain
tEnP Temp Sensor Step skipped if not model with heat.
HEAt Heater Step skipped if not heater-equipped.
L dC Door Lock Type L dC” for 24 VDC lock.
droP” or “drCL Door Status Door open or closed.
drUL” or “drLo Door Lock Status Door will lock.
8.8.8.8.” + all LEDs Display Test All display elements are lit.
PAxx” where xx = 1-3,
5-11
Keypad Test step Advance after all keypads are pressed.
A xx Top Cover Switch Test xx is either “CL” for closed or “oP” for open.
U xx Coin Vault Switch Test xx is either “CL” for closed or “oP” for open.
CxCx Coin Drop Test 1st x is number of Coin Drop #1 coins. 2nd x is number of Coin
Drop #2 coins.
Cxxx Machine Type/Size
drxx Drive Software Version
Number
xx is the drive software version number. Design 2 models only.
dPxx Drive Parameter Table
Ver s i on N um ber
xx is the drive parameter table version number. Design 2 models
only.
dt x Drive Type Value xx is the drive type value. Design 2 models only.
HFIL Hot Fill to Low Level All water outputs turned off when Low Level reached.
CFIL Cold Fill to Low Level All water outputs turned off when Low Level reached.
bFIL
Warm Fill to Low Level All water outputs turned off when Low Level reached.
bFIH Warm Fill to High Level All water outputs turned off when High Level reached.
S1” for supply or
C2Co” for
compartment
Supply #1 or Compartment
#2 Cold Fill
S2” for supply or
C2Ho” for
compartment
Supply #2 or Compartment
#2 Hot Fill
S3” for supply or
C3Co” for
compartment
Supply
#3 or Compartment
#3 Cold Fill