Programming Control
51
F8238301
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
21. Production Test Cycle (Enabled/
Disabled) “PtEn”
This option allows the owner to enable or disable
access to the production test cycle. Refer to
Production Test Cycle section for more information.
How to Program the Production Test
Cycle (Enabled/Disabled)
1. Control must be in Manual Mode. Refer to
Entering the Manual Mode.
2. Press the NORMAL/40C ( ) or the PERM
PRESS/40C ( ) keypad until “Prog” appears in
the display. Press the START (enter) keypad and
AtS1” will appear in the display.
3. Press the NORMAL/40C ( ) or the PERM
PRESS/40C ( ) keypad to scroll through the
programmable options until “PtEn” appears in
the display.
4. When “PtEn” appears in the display, press the
START (enter) keypad. The current Production
Test Cycle status will appear in the display.
on = Option Enabled (Default Setting)
oFF” = Option Disabled
5. Press the NORMAL/40C ( ) or the PERM
PRESS/40C ( ) keypad to change the current
status.
6. Press the START (enter) keypad when the
desired status appears in the display. The next
option, “rAEn”, will appear in the display.
NOTE: To program “rAEn” (Manual Rapid
Advance [on/off]), refer to option 22. To program
other options, refer to the appropriate section.
How to Exit Programming Feature
Press the PERM PRESS/60C (<) keypad until the
control returns to Ready Mode.
22. Manual Rapid Advance
(Enabled/Disabled) “rAEn”
This option allows the owner to enable or disable the
rapid advance feature. Refer to Rapid Advance
Feature section for more information.
How to Program the Manual Rapid
Advance (Enabled/Disabled)
1. Control must be in Manual Mode. Refer to
Entering the Manual Mode.
2. Press the NORMAL/40C ( ) or the PERM
PRESS/40C ( ) keypad until “Prog” appears in
the display. Press the START (enter) keypad and
AtS1” will appear in the display.
3. Press the NORMAL/40C ( ) or the PERM
PRESS/40C ( ) keypad to scroll through the
programmable options until “rAEn” appears in
the display.
4. When “rAEn” appears in the display, press the
START (enter) keypad. The current Manual
Rapid Advance status will appear in the display.
on = Option Enabled (Default Setting)
oFF” = Option Disabled
5. Press the NORMAL/40C ( ) or the PERM
PRESS/40C ( ) keypad to change the current
status.
6. Press the START (enter) keypad when the
desired status appears in the display. The next
option, “nCtd”, will appear in the display.
NOTE: To program “nCtd” (No Cycle Time
Display), refer to option 23. To program other
options, refer to the appropriate section.
How to Exit Programming Feature
Press the PERM PRESS/60C (<) keypad until the
control returns to Ready Mode.
>
<
>
<
<
>
<
>
<
>
<