Programming Control
F8238301
50
19. Cold Water Temperature “FC”
This option allows the owner to program the cold
water temperature for models equipped with heat.
How to Program Cold Water Temperature
1. Control must be in Manual Mode. Refer to
Entering the Manual Mode.
2. Press the NORMAL/40C ( ) or the PERM
PRESS/40C ( ) keypad until “Prog” appears in
the display. Press the START (enter) keypad and
AtS1” will appear in the display.
3. Press the NORMAL/40C ( ) or the PERM
PRESS/40C ( ) keypad to scroll through the
programmable options until “FC” appears in the
display.
4. When “FC” appears in the display, press the
START (enter) keypad. A number will appear in
the display. This number corresponds to the
current Cold Water Temperature value.
5. Press the NORMAL/40C ( ) or the PERM
PRESS/40C ( ) keypad to increase or decrease
the current Cold Water Temperature value to the
desired Cold Water Temperature value.
NOTE: Cold Water Temperature is selectable
between 35° and 194° Fahrenheit (2° and 90°
Celsius). Default temperature value is 35°
Fahrenheit (2° Celsius).
NOTE: Refer to option 16 to select Celsius or
Fahrenheit display.
6. Press the START (enter) keypad when the correct
number appears in the display. The next option,
Codn”, will appear in the display.
NOTE: To program “Codn” (Cooldown Enable/
Temperature), refer to option 20. To program other
options, refer to the appropriate section.
How to Exit Programming Feature
Press the PERM PRESS/60C (<) keypad until the
control returns to Ready Mode.
20. Cooldown Enable/Temperature
“Codn” (Models with Heat)
This option allows the owner to enable or disable the
Cooldown Water Temperature option. If enabled, the
owner can also set the cooldown water temperature.
How to Program Cooldown Enable/
Temperature
1. Control must be in Manual Mode. Refer to
Entering the Manual Mode.
2. Press the NORMAL/40C ( ) or the PERM
PRESS/40C ( ) keypad until “Prog” appears in
the display. Press the START (enter) keypad and
AtS1” will appear in the display.
3. Press the NORMAL/40C ( ) or the PERM
PRESS/40C ( ) keypad to scroll through the
programmable options until “Codn” appears in
the display.
4. When “Codn” appears in the display, press the
START (enter) keypad. A number, or “oFF”, will
appear in the display. The number corresponds to
the current Cooldown Water Temperature value,
and “oFF” appears when cooldown is disabled.
5. Press the NORMAL/40C ( ) or the PERM
PRESS/40C ( ) keypad to change the current
status.
NOTE: Cooldown Water Temperature is selectable
between 50° and 160° Fahrenheit (10° and 71°
Celsius). Default temperature value is OFF
6. Press the START (enter) keypad when the
desired value appears in the display.
NOTE: Refer to option 16 to select Celsius or
Fahrenheit display.
7. Press the START (enter) keypad when the correct
number appears in the display. The next option,
PtEn”, will appear in the display.
NOTE: To program “PtEn” (Prouction Test Cycle
[on/off]), refer to option 21. To program other
options, refer to the appropriate section.
How to Exit Programming Feature
Press the PERM PRESS/60C (<) keypad until the
control returns to Ready Mode.
>
<
>
<
>
<
To prevent personal injury, avoid contact
with inlet water temperatures higher than
125° Fahrenheit (51° Celsius) and hot
surfaces.