Programming Control
F8238301
16
Table 1 (continued)
Option
Number
Option
Display
Description Default Value Value Range
(4) “S1” Supply #1 (Design 2 models) ** on/oFF
(5) “S2” Supply #2 (Design 2 models) ** on/oFF
(6) “S3” Supply #3 (Design 2 models) ** on/oFF
(7) “S4” Supply #4 (Design 2 models) ** on/oFF
e. “SdUr” Supply Duration ** Press START keypad to access options
1. “SEC” Seconds ** 0-59
2. “nIn” Minutes ** 0-9
f. “AgSt” Agitate Step --
1. “AgEn” Agitate Step Enable/Disable ** on/oFF
2. “AdUr” Agitate Duration (in minutes) ** 1-30 for agitate types 1 or 2
3. “HEAt” Heat in Agitate (if heater is present) ** oFF/1/2**
g. “drAn” Drain Step on on/oFF
h. “SPIn” Extract Step --
1. “SPEn” Extract Step Enable/Disable ** on/oFF
2. “SSEC” Extract Seconds ** 0 - 59
3. “SnIn” Extract Minutes ** Intermediate Extract: Min. Step Time = 30
seconds, Max. Step Time = 3:59 minutes
Final Extract: Min. Step Time = 30
seconds, Max. Step Time = 9:59 minutes
4. “SSPd” Extract Speed (VFD only) ** 1-5* (Design 1)
1-6* (Design 2)
i. “Cnin”Cycle Time 0* 0-255 minutes
13 “SUPC” Supply/Compartment Dispenser
Programming (Design 1 models
only)
C
(Compartment)
C (Compartment)/
S (Supply Dispenser)
14 “bALr” Number of Balance Retries (VFD
only)
Design 1: 3
Design 2: 1
1-7
15 “IrA
” IR Access (On/Off) on on/oFF
16 “tFC” Fahrenheit/Celsius FAHr
(Fahrenheit)
FAHr (Fahrenheit)/CEL (Celsius)
17 “FH” Hot Water Temperature 140°F (60°C) 35°F-194°F/2°C-90°C
18 “FHC” Warm Water Temperature 100°F (38°C) 35°F-194°F/2°C-90°C
19 “FC” Cold Water Temperature 35°F (2°C) 35°F-194°F/2°C-90°C
20 “Codn” Cooldown Enable/Temperature oFF oFF or 50°F - 160°F /
10°C - 71°C
21 “PtEn”Production Test Cycle (On/Off) on on/oFF
22 “rAEn” Manual Rapid Advance (On/Off) on on/oFF
23 “nCtd” No Cycle Time Display oFF on/oFF
*Refer to programming section for value definition.
**Refer to the Cycle Chart for default cycle setting information.