Programming Control
53
F8238301
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
25. Slow Drain Detection Adjust
Value “SdAd”
This option allows the owner to increase the Slow
Drain Detection threshold by adding additional
seconds to the threshold value. When enabled, it
increases the time before a Slow Drain Error will
occur.
How to Program No Cycle Time Display
1. Control must be in Manual Mode. Refer to
Entering the Manual Mode.
2. Press the NORMAL/40C ( ) or the PERM
PRESS/40C ( ) keypad until “Prog” appears in
the display. Press the START (enter) keypad and
AtS1” will appear in the display.
3. Press the NORMAL/40C ( ) or the PERM
PRESS/40C ( ) keypad to scroll through the
programmable options until “SdAd” appears in
the display.
4. When “SdAd” appears in the display, press the
START (enter) keypad. The current Slow Drain
Detection Adjust value will appear in the display.
5. Press the NORMAL/40C ( ) or the PERM
PRESS/40C ( ) keypad to change the current
value.
NOTE: The Slow Drain Detection Adjust Value can
be set from 0 to 255 seconds. The default Slow
Drain Detection Adjust value is 0.
6. Press the START (enter) keypad when the
desired value appears in the display. The next
option, “SPAU”, will appear in the display.
NOTE: To program “SPAU” (Pause/Resume
Mode), refer to option 26. To program other
options, refer to the appropriate section.
How to Exit Programming Feature
Press the PERM PRESS/60C (<) keypad until the
control returns to Ready Mode.
26. Pause/Resume Mode (Enabled/
Disabled) “SPAU”
This option allows the owner to enable or disable
Pause/Resume Mode. When enabled, users can press
the START keypad three times (during first three
minutes of cycle) to pause the cycle.
How to Program the Pause/Resume
Mode (Enabled/Disabled)
1. Control must be in Manual Mode. Refer to
Entering the Manual Mode.
2. Press the NORMAL/40C ( ) or the PERM
PRESS/40C ( ) keypad until “Prog” appears in
the display. Press the START (enter) keypad and
AtS1” will appear in the display.
3. Press the NORMAL/40C ( ) or the PERM
PRESS/40C ( ) keypad to scroll through the
programmable options until “SPAU” appears in
the display.
4. When “SPAU” appears in the display, press the
START (enter) keypad. The current Pause/
Resume status will appear in the display.
on = Option Enabled
oFF” = Option Disabled (Default Setting)
5. Press the NORMAL/40C ( ) or the PERM
PRESS/40C ( ) keypad to change the current
status.
6. Press the START (enter) keypad when the
desired status appears in the display. The next
option, “AtS2”, will appear in the display.
NOTE: To program “AtS2” (Normal/60C Vend
Price), refer to option 27. To program other
options, refer to the appropriate section.
How to Exit Programming Feature
Press the PERM PRESS/60C (<) keypad until the
control returns to Ready Mode.
>
<
>
<
<
>
<
>
<
>
<