Test Descriptions
Diagnostic Test
To start this test, follow steps 14 in
How to Enter
Testing Feature.
Next, while pressing and holding
the NO HEAT pad with one hand, press the HIGH
TEMP pad with the other hand. The Diagnostic Test
is designed to exercise various relays, signals, LED's,
and VFD time displays. Chart 12 defines each step of
the Diagnostic Test routine. To exit this test see
NOTE below.
Diagnostic Test Routine
Time
Display
Illuminated
LEDs/VFD
Motor
Relay
Heater
Relay
Signal
111 All ON ON ON OFF
222 All OFF ON ON OFF
333 All ON OFF OFF OFF
444 All ON OFF OFF OFF
555 All OFF OFF OFF OFF
666 All ON OFF OFF LOW
777 All OFF ON OFF MED
888 All ON ON ON HIGH
CHART 12
NOTE: When the last step in the table is finished,
the routine starts again from the beginning. To
exit, press any pad or open the dryer door. The
VFD display will revert back to the Ready mode.
See
Figure 3
.
Dryer-On Temperature Test
To start this test, follow steps 14 in
How to Enter
Testing Feature.
Next, while pressing and holding
the START pad with one hand, press the LOW TEMP
pad with the other hand. This test will run a chosen
cycle while displaying the temperature on the VFD
display.
The temperature will be displayed in either Fahrenheit
or Celsius depending on how the control was
programmed (the default is Fahrenheit). When the
test is complete, the control will revert back to the
Ready mode. To end the test before the cycle is
complete, press and hold the START pad with one
hand, at the same time press the LOW TEMP pad
with the other hand.
Thermistor Temperature Display Test
To start this test, follow steps 14 in
How to Enter
Testing Feature.
Next, while pressing and holding
the START pad with one hand, press the MED TEMP
pad with the other hand. This test simply displays the
temperature sensed at the thermistor in either
Fahrenheit or Celsius (the default is Fahrenheit). To
exit this test, open the dryer door or press and hold
the START pad with one hand, then press the MED
TEMP pad with the other hand. When the test is
complete the control will revert back to the Ready
mode.
Coin Vault Opening Test
To start this test, follow steps 14 in
How to Enter
Testing Feature.
Next, press the HIGH TEMP pad.
The VFD display will show U:OO,
Figure 98
.
DRYING
DOOR OPEN
COOL DOWN
PRICE
TIME REMAINING
INSERT COINS
PUSH START
C177IE1A
Figure 98