16. LOW TEMP Temperature
LdE
This option allows the user to set the maximum
temperature in the LOW TEMP cycle.
How to Program LOW TEMP Temperature
LdE
1. Control must be in Special Mode. Refer to
Section VII.
2. While pressing and holding the HIGH TEMP
pad with one hand, press the MED TEMP pad
with the other hand. Programmable option
number 1 (Audio Signal SIg) will appear in
the VFD,
Figure 54
.
DRYING
DOOR OPEN
COOL DOWN
PRICE
TIME REMAINING
INSERT COINS
PUSH START
C146IE1A
Figure 54
3. Press the LOW TEMP (+) pad or the NO
HEAT () pad to scroll through the
programmable options until LdE appears in
the VFD,
Figure 55
.
DRYING
DOOR OPEN
COOL DOWN
PRICE
TIME REMAINING
INSERT COINS
PUSH START
C162IE1A
Figure 55
4. When LdE appears in the VFD, press the
START pad. A three-digit number will appear
in the VFD.
NOTE: The number appearing in the VFD is the
current number that was selected from
Chart 5
on
this page.
5. Locate the desired three-digit number in the
first column of
Chart 5
.
6. Press the LOW TEMP (+) pad or the NO
HEAT () pad to increase or decrease the
current three-digit number to the desired three-
digit number from
Chart 5
,
Figure 56
.
NORMAL
HIGH
TEMP
PERM
PRESS
MED TEMP
DELICATES
LOW
TEMP
TUMBLE
NO
HEAT
START
Press this pad to
scroll ahead or
increase (+) values
Press this pad to
scroll back or
decrease (-) values
Press this pad to
choose (enter) selected
options or values
C147IE1A
Figure 56
7. Press the START pad when the correct three-
digit number appears in the VFD. The next
programmable option, Add, will appear in the
VFD.
NOTE: To program Add (Additional Time), see
the following page. To program other options,
refer to the appropriate section.
LOW TEMP Temperature LdE
LOW TEMPERATURE VALUE CHART
VALU FAHRENHHEIT TEMP CELSIUS TEMP
000 100°F 38°C
001 105°F 41°C
002 110°F 43°C
003 115°F 46°C
004 120°F 49°C
005 125°F 52°C
006 130°F 54°C
CHART 5
How to Exit Programming Feature
1. Be sure service door has been opened and
closed. Refer to Section VI.
2. While pressing and holding the HIGH
TEMP pad with one hand, press the
MED TEMP pad with the other hand. The
control will revert back to the Ready mode.
See