501506
2. Normal Vend Price nPr
This option allows the user to set the normal (heated
cycle) vend pricing which will be displayed in the VFD
when in the Ready mode. The vend price
programmed in this option is used for all cycles except
the NO HEAT cycle.
Program this option whenever a heated cycle vend
price needs to be changed.
How to Set the Normal Vend Price nPr
1. Control must be in Special Mode. Refer to
Section VII.
2. While pressing and holding the HIGH TEMP
pad with one hand, press the MED TEMP pad
with the other hand. Programmable option
number 1 (Audio Signal SIg) will appear in
the VFD,
Figure 12
.
DRYING
DOOR OPEN
COOL DOWN
PRICE
TIME REMAINING
INSERT COINS
PUSH START
C146IE1A
Figure 12
3. Press the LOW TEMP (+) pad or the NO
HEAT () pad to scroll through the
programmable options until nPr appears in
the VFD,
Figure 13
.
DRYING
DOOR OPEN
COOL DOWN
PRICE
TIME REMAINING
INSERT COINS
PUSH START
C148IE1A
Figure 13
4. When nPr appears in the VFD, press the
START pad. The current number of coins
required to fulfill the vend price will appear in
the VFD.
5. Press the LOW TEMP (+) pad or the NO
HEAT () pad to increase or decrease the
current number of coins to the desired number
of coins,
Figure 14
.
NORMAL
HIGH
TEMP
PERM
PRESS
MED TEMP
DELICATES
LOW
TEMP
TUMBLE
NO
HEAT
START
Press this pad to
scroll ahead or
increase (+) values
Press this pad to
scroll back or
decrease (-) values
Press this pad to
choose (enter) selected
options or values
C147IE1A
Figure 14
6. When the correct number of coins appears in
the VFD, press the START pad to enter the
corrected number. The next programmable
option, SPA, will appear in the VFD.
NOTE: To program SPA (Special Vend A), see
the following page. To program other options,
refer to the appropriate section.
How to Exit Programming Feature
1. Be sure service door has been opened and
closed. Refer to Section VI.
2. While pressing and holding the HIGH
TEMP pad with one hand, press the
MED TEMP pad with the other hand. The
control will revert back to the Ready mode.
See
Figure 3
.
Page view 24