Section 5 Service Procedures
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
To reduce the risk of electric shock, fire, explosion, serious injury or death:
Disconnect all electric power to the machine and accessories before servicing.
Close gas shut-off valve to gas dryer before servicing.
Never start machine with any guards/panels removed.
Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the machine is properly grounded.
Washer motor not grounded! Disconnect electric power before servicing motor.
W502
WARNING
IMPORTANT: When installing lint filter, be sure to
install the filter with the words facing the front of
the dryer. If filter is installed backwards, lint will
accumulate in exhaust system, which can adversely
affect dryer performance.
e. Remove three screws holding the air duct to the
front bulkhead inside cylinder. Refer to
Figure 41.
f. Carefully lift air duct out of dryer.
IMPORTANT: When reassembling, be sure seal on
exhaust fan cover makes airtight seal on flange of
duct. Refer to Figure 40. If the seal is installed
improperly, the airflow through the exhaust system
will be restricted which can adversely affect dryer
performance.
71. DRYER MOTOR AND EXHAUST
ASSEMBLY
a. While supporting the access panel, remove two
screws from bottom edge of access panel. Refer
to Figure 27.
b. Gently lower the access panel to disengage
locators from bottom edge of front panel. Refer
to Figure 35.
c. Open loading door, remove screw, and lift filter
out of bulkhead.
d. Remove screws holding air duct to front
bulkhead (inside cylinder). Refer to Figure 41.
IMPORTANT: When reassembling, be sure seal on
exhaust fan cover makes airtight seal on flange of
duct. Refer to Figure 42. If the seal is installed
improperly, the airflow through the exhaust system
will be restricted, which can adversely affect dryer
performance.
e. Disconnect wires from thermostat.
NOTE: Refer to wiring diagram when rewiring
thermistor.
f. Remove screw holding ground wire to dryer
base. Refer to Figure 42.
g. Remove cylinder belt from idler and motor
pulleys. Refer to Figure 43.
h. Disengage motor wire harness terminal block
from motor switch by pressing in on the
movable locking tabs (located on each end of
the terminal block) and pulling away from
motor. Refer to Figures 46 and 47.
i. Remove two screws holding motor mounting
bracket to dryer base. Refer to Figure 42.
Figure 42
To reduce the risk of serious injury or death
by carbon monoxide and other gases in
gas dryers, carefully read and follow all
instructions given in this section.
W005
WARNING
Cover
Attaching
Screws
Thermostat
Motor
Mount
Attaching
Screws
D400SE1E
Ground
Wire
To reduce the risk of serious injury or death
by carbon monoxide and other gases in
gas dryers, carefully read and follow all
instructions given in this section.
W005
WARNING