Alliance Laundry Systems LTS99A*N1180 Service Manual Page 115

  • Download
  • Add to my manuals
  • Print
  • Page
    / 126
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 114
801803 113
Section 7 Dryer Test Procedures
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
To reduce the risk of electric shock, fire, explosion, serious injury or death:
Disconnect all electric power to the machine and accessories before servicing.
Close gas shut-off valve to gas dryer before servicing.
Never start machine with any guards/panels removed.
Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the machine is properly grounded.
Washer motor not grounded! Disconnect electric power before servicing motor.
W502
WARNING
88. DRIVE MOTOR
Refer to Figure 65.
a. Remove motor and exhaust assembly. Refer to
Paragraph 71.
b. Disconnect motor wire harness at motor
disconnect block.
NOTE: Refer to wiring schematic, Section 8, for
internal motor switch wires.
NOTE: Drive Motor Resistance
120 Volt 2,460 – 3,100 Ohms
240 Volt 10,000 - 13,000 Ohms
Figure 65
2
643 5
1
G
Drive
Motor
Motor and
Exhaust
Assembly
D326SE3A
1
2
4
6
5
3
Motor
Disconnect
Block
Motor
Switch
Page view 114
1 2 ... 110 111 112 113 114 115 116 117 118 119 120 ... 125 126

Comments to this Manuals