102 801803
Section 5 Service Procedures
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
To reduce the risk of electric shock, fire, explosion, serious injury or death:
Disconnect all electric power to the machine and accessories before servicing.
Close gas shut-off valve to gas dryer before servicing.
Never start machine with any guards/panels removed.
Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the machine is properly grounded.
Washer motor not grounded! Disconnect electric power before servicing motor.
W502
WARNING
79. TERMINAL BLOCK OR POWER CORD
a. Terminal Block:
(1) While supporting the access panel, remove
two screws from bottom edge of access
panel. Refer to Figure 27.
(2) Gently lower the access panel to disengage
locators from bottom edge of front panel.
Refer to Figure 35.
(3) Remove two screws holding bottom tabs on
front panel to dryer side panels. Refer to
Figure 28. Swing bottom of front panel
away from dryer far enough to disengage
hold-down clips and locators from cabinet
top.
(4) Disconnect wires from door switch. Refer
to Figure 34.
NOTE: Refer to wiring diagram when rewiring
switch.
(5) Remove two cabinet top hold-down screws.
Refer to Figure 29.
(6) Lift cabinet top to a vertical position by
hinging it on the rear hold-down brackets.
Refer to Figure 30.
NOTE: When servicing, cabinet top may be raised
and hinged on the rear hold-down brackets, or
supported against wall behind the dryer.
(7) Remove all wires from terminal block.
NOTE: Refer to wiring diagram when rewiring
terminal block.
(8) Remove screw holding terminal block to
rear bulkhead. Refer to Figure 56.
NOTE: Do not let terminal block insulation drop
when removing the block. Insulation must be in
place when reinstalling block.
Figure 56
Cabinet
Top
Terminal Block
Attaching
Screw
Terminal
Block
D353SE3A