Alliance Laundry Systems LTS99A*N1180 Service Manual Page 113

  • Download
  • Add to my manuals
  • Print
  • Page
    / 126
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 112
801803 111
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
To reduce the risk of electric shock, fire, explosion, serious injury or death:
Disconnect all electric power to the machine and accessories before servicing.
Close gas shut-off valve to gas dryer before servicing.
Never start machine with any guards/panels removed.
Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the machine is properly grounded.
Washer motor not grounded! Disconnect electric power before servicing motor.
W502
WARNING
Section 7
Dryer Test Procedures
IMPORTANT: Electrical test procedures in this
service manual are performed by using a Volt-Ohm
meter. Tests can also be performed using a multi-
meter or any other electrical testing equipment with
which the service person is familiar.
86. TIMER CONTACTS
Refer to Figure 64.
a. Disconnect wires from timer, except timer
motor wires.
NOTE: Refer to appropriate wiring diagram when
rewiring timer.
b. Manually rotate timer out of “OFF” position
and into cycle.
c. Set test meter to read Ohms. The following
readings should be found:
(1) Motor circuit test – L1 and M = “zero”
Ohms (closed)
(2) Heat circuit test – L2 and H = “zero” Ohms
(closed)
(3) Timer motor test – T and N =
approximately 2460-3100 Ohms or apply
live power to timer motor terminals and
motor should run.
NOTE: Timer Motor Resistance:
120 Volt, 60 Hz 2,460 – 3,100 Ohms
240 Volt 10,900 – 13,000 Ohms
24 Volt 80 – 130 Ohms
(4) Rotate timer to “cooldown” (5 minutes
before “OFF”). “Infinite” (open) reading
should be found between L1 and H.
(5) Rotate timer to “OFF” position. “Infinite”
(open) reading should be found between L1
and M and between L1 and H.
NOTE: Timer motor power is supplied through M
terminal.
Figure 64
Ground
Terminal
Timer
Motor
Wires
“M”
“N”
“M”
“H”
Page view 112
1 2 ... 108 109 110 111 112 113 114 115 116 117 118 ... 125 126