Alliance Laundry Systems LTS99A*N1180 Service Manual Page 55

  • Download
  • Add to my manuals
  • Print
  • Page
    / 126
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 54
801803 53
Section 5 Service Procedures
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
To reduce the risk of electric shock, fire, explosion, serious injury or death:
Disconnect all electric power to the machine and accessories before servicing.
Close gas shut-off valve to gas dryer before servicing.
Never start machine with any guards/panels removed.
Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the machine is properly grounded.
Washer motor not grounded! Disconnect electric power before servicing motor.
W502
WARNING
36. PRESSURE SWITCH
a. Go to rear of washer and remove screws
holding rear panel to side panels of control
cabinet. Refer to Figure 7.
b. Locate pressure switch on control shield and
disconnect wires from switch at disconnect
block.
c. Disconnect pressure hose from pressure switch.
IMPORTANT: When installing pressure switch,
blow air into hose before connecting hose to switch
to remove any moisture that may have accumulated
in hose.
d. Squeeze locking tabs in on pressure switch and
push switch out toward rear of control shield.
Refer to Figure 7.
37. CONTROL CABINET
a. Remove dryer. Refer to Paragraph 33.
b. Remove screws holding control panel to
control cabinet. Refer to Figure 7. Remove
panel.
c. Remove screws holding control cabinet bottom
to control cabinet. Refer to Figure 7.
d. Remove screws holding control shield (with
controls attached) to bottom rear flange of
control cabinet. Refer to Figure 7.
e. Remove screws holding control to rear of
control cabinet. Refer to Figure 7.
f. Remove screws holding control cabinet to top
flange of side panels. Refer to Figure 7.
g. Carefully lift control cabinet assembly off
washer.
h. Remove screws holding left, right and rear
control cabinets together. Refer to Figure 7.
38. WASHER LOWER ACCESS PANEL
a. While supporting the lower access panel,
remove two screws from bottom edge of lower
access panel. Refer to Figure 8.
b. Gently lower the access panel to disengage
panel locators from bottom edge of front panel.
Figure 8
H202SE1A
Screws
Lower
Access Panel
Panel
Locators