Alliance Laundry Systems LTS99A*N1180 Service Manual Page 119

  • Download
  • Add to my manuals
  • Print
  • Page
    / 126
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 118
801803 117
Section 7 Dryer Test Procedures
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
To reduce the risk of electric shock, fire, explosion, serious injury or death:
Disconnect all electric power to the machine and accessories before servicing.
Close gas shut-off valve to gas dryer before servicing.
Never start machine with any guards/panels removed.
Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the machine is properly grounded.
Washer motor not grounded! Disconnect electric power before servicing motor.
W502
WARNING
(2) Motor with switch on pulley end
Press the tip of a small bladed screwdriver
into the slot located between top of motor
switch and plastic clip. Lift up on handle of
screwdriver until both clip and thermal
overload protector detach from motor
switch. Refer to Figure 67.
d. Attach the thermal overload protector removed
in Step “c” to the new motor switch.
e. Install new motor switch onto motor and
reconnect motor switch leads removed in Step
“b”. Refer to Figure 71.
f. Test motor switch by following the step-by-
step procedures included in Paragraph 45.
g. Before reinstalling the motor assembly, apply
power (120 VAC) directly to motor terminals 4
and 5. Then start and run the motor at least 6
times, making sure the motor and switch are
operating properly.
NOTE: The dryer manufacturer and parts
suppliers are not liable for improper switch
installation.
Figure 67
D359SE3A
Thermal
Overload
Protector
Plastic
Clip
Motor
Switch
Top Of
Motor
Switch