Page view 88
801803 87
Section 5 Service Procedures
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
To reduce the risk of electric shock, fire, explosion, serious injury or death:
Disconnect all electric power to the machine and accessories before servicing.
Close gas shut-off valve to gas dryer before servicing.
Never start machine with any guards/panels removed.
Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the machine is properly grounded.
Washer motor not grounded! Disconnect electric power before servicing motor.
W502
WARNING
66. BURNER HOUSING AND HEAT SHROUD
(Gas Models)
a. While supporting access panel, remove two
screws from bottom edge of access panel. Refer
to Figure 27.
b. Gently lower access panel to disengage locators
from bottom edge of front panel. Refer to
Figure 35.
c. Disconnect igniter wires at disconnect blocks,
sensor wires from sensor terminals, and wires
from gas valve coils at the quick disconnect
blocks. Refer to Figure 37.
d. Remove screw from right side of burner
housing, while holding burner tube in place.
Refer to Figure 39.
e. Gently move burner tube toward rear of dryer to
disengage tab from slot on left side of burner
housing. Refer to Figure 37.
f. Carefully rotate burner tube and igniter
counterclockwise so tab is at 8 o’clock
position.
g. Move air shutter end of burner tube slightly to
the right and CAREFULLY remove burner
tube and igniter assembly out through front of
dryer.
IMPORTANT: The igniter is very fragile. Be careful
not to damage it during removal.
h. Remove screw holding burner housing to heat
shroud. Refer to Figure 37.
i. Remove screw holding front of burner housing
to dryer base and remove housing out through
front of dryer. Refer to Figure 39.
j. Remove two screws holding heat shroud to
heater box and remove heat shroud out through
front of dryer.
67. LIMIT THERMOSTAT
a. While supporting the access panel, remove two
screws from bottom edge of access panel. Refer
to Figure 27.
b. Gently lower the access panel to disengage
locators from bottom edge of front panel. Refer
to Figure 35.
c. Disconnect wires and remove screws holding
limit thermostat to burner housing (gas models)
or element plate (electric models). Refer to
Figure 39.
ELECTRIC MODELS GAS MODELS
Figure 39
Heater
Assembly
Heater Wire
Connections
Limit
Thermostat
Thermal
Fuse
Screw
D243SE3A
Limit
Thermosta
t
Burner
Tube
Screw
Burner Tube
Screw
Gas Valve Handle
(Shown in Closed
Position)
Base
Burner
Housing
D244SE3B