Section 5 Service Procedures
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
To reduce the risk of electric shock, fire, explosion, serious injury or death:
Disconnect all electric power to the machine and accessories before servicing.
Close gas shut-off valve to gas dryer before servicing.
Never start machine with any guards/panels removed.
Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the machine is properly grounded.
Washer motor not grounded! Disconnect electric power before servicing motor.
W502
WARNING
IMPORTANT: When installing inner basket, the
following steps must be taken to ensure that the seal
is properly orientated:
c. Install inner basket assembly by pushing all the
way into outer tub. Refer to Figure 26, Step 1.
d. Slightly pull out inner basket about 1/4 inch to
ensure that the bearing housing seal lips are not
rolled over. Refer to Figure 26, Step 2.
NOTE: If inner basket is pulled out more than 3/8
inch (past step on trunnion shaft), repeat Steps “c”
and “d”.
e. Fully reseat inner basket. Refer to Figure 26,
Step 3.
f. Install pulley and cap screw. Be careful not to
push the shaft forward while tightening the
screw.
IMPORTANT: When installing pulley, always use a
new cap screw to prevent screw from loosening
during operation. Use a thread tap to clean old
Loctite out of pulley screw receiving hole before
installing new screw. This ensures that inner basket
and pulley properly seat.
NOTE: When installing new cap screw, apply a
thread locking compound to screw threads and
torque new cap screw to 240 minimum to 260
maximum inch pounds (27.5 to 29.7 Nm).
53. DRYER ACCESS PANEL
Refer to Figure 27.
a. While supporting access panel, remove two
screws from bottom edge of panel.
b. Gently lower access panel to disengage panel
locators from bottom edge of front panel.
c. Remove access panel.
Figure 27
Access
Panel
Panel
Attaching
Screws