© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
To reduce the risk of electric shock, fire, explosion, serious injury or death:
Disconnect all electric power to the machine and accessories before servicing.
Close gas shut-off valve to gas dryer before servicing.
Never start machine with any guards/panels removed.
Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the machine is properly grounded.
Washer motor not grounded! Disconnect electric power before servicing motor.
W502
WARNING
Section 8
Internal Wiring of Dryer Motor Switch
Figure 71
R
R
S
26 4 3 5 1
MAIN
START
ORANGE/COPPER
CUSTOMER CIRCUIT
OVERLOAD
PROTECTOR
BLUE/BROWN
BLACK/COPPER
YELLOW/COPPER
PUSH TO
START
LINE
SWITCH SHOWN IN START POSITION
R.S.P.C.
26 4 3 5 1
G
D329SE3D
G
Motor Switch
Attaching Screws