Troubleshooting
12. Contactor Analysis (SP)
Contactor Analysis (SP)
Is there voltage (120 Volts
AC) between the SPIN wire
and
the ACN
?
3A
2A
1A
NO
Disconnect
power to the machine.
Using an ohm meter, is there
continuity between the coils
on the KM5 contactor?
YES
Inspect the motor wiring and repair
or replace it as needed.
Inspect the motor and replace it as
needed.
YES
Replace the KM5 contactor.
NO
Manually operate the
KM5 contactor. Does
the motor function?
NO
Examine the wiring to terminal
strip 27. Repair and/or replace
the wiring as needed.
Replace the KM5 contactor.
YES
The contactor is not energizing.