Alliance Laundry Systems CABINET HARDMOUNT UC125VNV Service Manual Page 40

  • Download
  • Add to my manuals
  • Print
  • Page
    / 110
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 39
38 F232203
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Troubleshooting
8. No Motor Function (SP)
No Motor Function (SP)
With the machine running, the water
valves on and the machine holding
water (i.e., filling up), the basket has
no extract function (i.e., SP).
4A
NO
YES
Is there voltage
(120 Volts AC) across
the coil of the KM5 and
the KM4 contactors?
Is there voltage
(120 Volts AC) between
wire SPIN on the output
board and the ACN?
Is there voltage
(120 Volts AC) between the
input side of the SP fuse
and the ACN?
Is there voltage
(120 Volts AC) between the
output side of the SP fuse
and the ACN?
NO
YES
Replace the output board.
NO
YES
1A
2A
2A
3A
Replace the SP fuse.
NO
Inspect the motor.
Repair/replace the motor
as needed.
YES
Inspect the contactors'
wiring connections.
CHM402S
4A
1A
2A
2A
3A
2A
3A
Page view 39
1 2 ... 35 36 37 38 39 40 41 42 43 44 45 ... 109 110

Comments to this Manuals